摘要:在新世紀(jì),建筑給排水將擔(dān)負(fù)新的歷史重任,面臨新的挑戰(zhàn)。建筑給排水將更突出以人為本的原則,并將重點(diǎn)調(diào)整到民用建筑與工業(yè)建筑并重,公共建筑與居住建筑并重,冷水供應(yīng)與熱水供應(yīng)并重,走上全面、均衡、務(wù)實(shí)、安全的發(fā)展之路。建筑給水排水屬于應(yīng)用工程,是整個(gè)建筑設(shè)計(jì)中一個(gè)相當(dāng)重要的環(huán)節(jié),也是建筑設(shè)計(jì)中必不可少的。 本文針對(duì)鄭州市體育運(yùn)動(dòng)集訓(xùn)中心五號(hào)樓,結(jié)合對(duì)設(shè)計(jì)標(biāo)準(zhǔn)、規(guī)范的理解,對(duì)該建筑的給水系統(tǒng)、排水系統(tǒng)、消防水系統(tǒng)、熱水系統(tǒng),主要以設(shè)計(jì)計(jì)算說(shuō)明的形式,進(jìn)行了初步探討。 根據(jù)設(shè)計(jì)資料,市政提供的常年的水壓為33m水柱,本建筑的高度為65.70m,所以應(yīng)該分區(qū)供水,根據(jù)設(shè)計(jì)規(guī)范的有關(guān)規(guī)定,負(fù)一至五層為低層,市政管網(wǎng)供水,六至十一層,十二至十八層變頻調(diào)速水泵增壓給水。 排水系統(tǒng)采用合流制的排污體系,即生活污、廢水不進(jìn)行局部處理,合流排出室外。地下室集水坑,設(shè)潛污泵排水。處理后與廢水一起排入市政污水管網(wǎng)。 高層居民樓熱水系統(tǒng),沒有城市熱力網(wǎng)時(shí),一般采用集中熱水供應(yīng)系統(tǒng),建筑附近有表壓為0.33MPa的蒸汽熱源可用。 關(guān)鍵詞 高層建筑;消火栓滅火系統(tǒng);自動(dòng)噴水滅火系統(tǒng)
Abstract:In the new century, building water supply and drainage will shoulder the historical responsibility of new, facing new challenges. Building water supply and drainage will highlight the people-oriented principle, and will focus on the adjustment to the civil architecture and industrial architecture both, both public buildings and residential building, and the cold water supply and hot water supply, into a comprehensive, balanced, practical, safe development road. Building water supply and drainage and belongs to the application of engineering, is a very important part of the whole building design, is also essential in architectural design. According to the Zhengzhou City Sports Training Center five building, according to the design standard, the understanding of the specification, the water supply system, the drainage system, fire water system, hot water system, mainly in the design calculation shows how the form, has carried on the preliminary discussion. According to the design data, municipal provide perennial pressure for the 33m column, the building height of 65.70m, so it should be the regional water supply, according to the relevant provisions of design code, a negative one to five layers of low layer, municipal water supply pipe network, six to eleven, twelve to eighteen layers of variable frequency speed water pump pressurized water supply. Drainage system with combined sewage system, sewage, wastewater is not discharged outside local processing, confluence. The basement sump, sewage submersible pump drainage. After treatment with wastewater discharged to municipal sewage pipe network. Water heating system for high-rise residential buildings, no city thermal net, generally adopts the centralized hot water supply system, building near a gauge for 0.33MPa steam heat source available. Key words High-rise Building Fire Hydrant System Automatic Sprinkler System |