摘要:設(shè)計(jì)建筑是鹽城市朗香郡3號(hào)樓,為一22層民用建筑,包含一層地下室、物業(yè)和若干層住宅。該建筑東側(cè)及南側(cè)的城市道路旁,有一市政給水干管可做為該建筑物的水源,管徑為DN300,常年資用水頭為26米,與樓距離18米,管頂埋深1.5米。城市排水管道在擬建建筑物西側(cè)和北側(cè),管徑為DN400,管頂埋深為2.5米,與樓距離20米。建筑附近有表壓為0.20MPa的蒸汽熱源。 本次設(shè)計(jì)分為4部分內(nèi)容:建筑給水設(shè)計(jì)、建筑排水設(shè)計(jì)、建筑消防設(shè)計(jì)、建筑熱水設(shè)計(jì)。 建筑給水設(shè)計(jì)進(jìn)行豎向分區(qū),一層到五層設(shè)為低區(qū),由市政干管26m常年資用水頭供水。六層到十四層設(shè)為中區(qū),十五二十二層設(shè)為高區(qū),中區(qū)與高區(qū)分別由各自變頻泵組供給水壓。給水管道選擇三型無(wú)規(guī)共聚聚丙烯(PP-R)管。 建筑排水設(shè)計(jì)采用污廢合流制。將二層到二十二層設(shè)為高層,設(shè)專用通氣立管通氣。一層單獨(dú)排出,與高層排水系統(tǒng)的專用通氣立管相連。排水管道選擇硬聚乙烯塑料管(UPVC)。雨水排水系統(tǒng)選擇外排水系統(tǒng),重力半有壓流的87雨水斗系統(tǒng),無(wú)溝排水,單斗系統(tǒng)。 建筑消防設(shè)計(jì)中建筑的消火栓的靜水壓力不超過(guò)建筑給排水設(shè)計(jì)手冊(cè)規(guī)定消防栓的最大靜水壓力1.0MPa,采用不分區(qū)的消火栓系統(tǒng)。根據(jù)規(guī)范要求,在地下室內(nèi)設(shè)自動(dòng)噴水滅火系統(tǒng)。自動(dòng)噴水滅火系統(tǒng)選擇濕式自動(dòng)噴水滅火系統(tǒng)。 建筑熱水設(shè)計(jì)選擇間接加熱方式,閉式,立管循環(huán)方式,全天循環(huán)方式,機(jī)械循環(huán)方式,下行上給供水方式。熱水管道選擇交聯(lián)聚乙烯(PE-X)管。 關(guān)鍵詞 高層建筑;給水;消防;排水;熱水
Abstract: Architecture is designed Langxiangjun Yancheng County Building 3, is a 22-storey residential construction and includes a layer of basement, residential properties and certain layers. The building east and south of the city beside the road, there is a municipal water mains water can do for a building, diameter of DN300, perennial owned water head of 26 meters, and 18 meters from the floor, the top tube depth 1.5 m. City sewer west and north of the proposed building, diameter of DN400, tube top depth is 2.5 m, and 20 m from the floor. Building near the gauge pressure of 0.20MPa steam heat. The design is divided into four parts: building water supply design, building drainage design, building fire design, architectural design hot water. Building water design vertical partitions, one layer to five-set lower zone, 26m from the municipal mains water head perennial water resources. Set of six to fourteen layers area, fifteen to twenty story high area, Central region with high frequency by the respective pump supply pressure. Select three type water pipe polypropylene random copolymer (PP-R) pipe. Construction of drainage system design using sewage waste confluence. The story is set to the 22-storey high-rise, set up special ventilation vent riser. Layer separately discharged with senior drainage system connected to a dedicated vent riser. Select the hard polyethylene drainage pipes plastic pipe (UPVC). Stormwater drainage system outside the drainage system selection, gravity flow of 87 semi-pressurized water bucket system, no drainage ditch, single bucket system. Architectural design of the building fire hydrant hydrostatic pressure does not exceed specified building water hydrant design manual maximum hydrostatic pressure 1.0MPa, using non-partitioned hydrant system. According to the specification requirements, in the basement equipped with automatic sprinkler system. Select wet sprinkler system sprinkler system. Architectural design choices indirect hot water heating, closed, risers cycle way, all-day round-robin fashion, mechanical cycle way, way down on to the water supply. Select crosslinked polyethylene water pipes (PE-X) pipe. Keywords High-rise building Water supply Fire Drainage Hot water |