需要金幣:![]() ![]() |
資料包括:完整論文 | ![]() |
![]() |
轉(zhuǎn)換比率:金額 X 10=金幣數(shù)量, 例100元=1000金幣 | 論文字?jǐn)?shù):26239 | ![]() | |
折扣與優(yōu)惠:團(tuán)購最低可5折優(yōu)惠 - 了解詳情 | 論文格式:Word格式(*.doc) | ![]() |
摘要:本設(shè)計為蘇州市水利局綜合樓建筑給水排水設(shè)計。包括建筑給水系統(tǒng)、建筑排水系統(tǒng)、建筑消防系統(tǒng)、建筑熱水系統(tǒng)的設(shè)計。 該建筑東側(cè)及南側(cè)的城市道路旁,有一市政給水干管可做為該建筑物的水源,管徑為DN300,常年資用水頭為24米,與樓距離20米,管頂埋深1.5米。其中排水系統(tǒng)還包括雨水系統(tǒng)設(shè)計,消防系統(tǒng)包括消火栓系統(tǒng)和自動噴水滅火系統(tǒng)。建筑給水系統(tǒng)將本建筑物分成三個區(qū),低區(qū)為依靠市政管網(wǎng)水壓直接供水,中區(qū)和高區(qū)采用變頻水泵供水方式,即用變頻泵供水。排水系統(tǒng)采用污廢水合流系統(tǒng),污廢水進(jìn)入化糞池處理,建筑底層單獨(dú)設(shè)置排水立管將污水排至化糞池。雨水系統(tǒng)采用重力半有壓流系統(tǒng)。消防給水系統(tǒng)中的消火栓系統(tǒng)采用兩股水柱同時到達(dá)。自動噴水滅火系統(tǒng)在辦公室、走廊和客房布置。消防水池的體積為室內(nèi)消防水量、噴淋系統(tǒng)水量和室外消防水量之和。熱水系統(tǒng)中熱源為建筑物附近的表壓為0.20MPa的蒸汽熱源。加熱器采用半容積式水加熱器。給水管材采用三型聚丙烯管(PP-R)管材,排水管道采用硬聚氯乙烯管(UPVC),消防管材選用鋼管,熱水管材選用交聯(lián)聚乙烯(PEX)。 關(guān)鍵詞 給水;消防;排水;噴淋
Abstract:The design for the Suzhou Municipal Water Conservancy Bureau Building Water and Drainage Design. Including building water supply systems, construction of drainage systems, building fire protection systems, building hot water system design. The building east and south of the city beside the road, there is a municipal water mains water can do for a building, diameter of DN300, perennial owned water head of 24 m and 20 m from the floor, the top tube depth 1.5 m. Stormwater drainage system which also includes system design, fire protection systems, including fire hydrant systems and automatic sprinkler system. Building water supply system of the building is divided into three zones, the lower zone is to rely on the municipal pipe network pressure direct water supply, the area and the upper zone to the pump tank water supply, which uses variable frequency pump water. Sewage and waste water drainage system merging systems, sewage and wastewater into the septic tank treatment, construction drainage bottom riser will be individually set to a septic tank effluent discharge. Gravity drainage systems using semi-pressurized flow system. Fire water supply system in the fire hydrant system uses two jets of water at the same time to arrive. Automatic sprinkler system in offices, corridors and rooms furnished. The interior volume of fire water fire water, water sprinkler system and outdoor fire water combined. Hot water system for the building near a heat source gauge pressure of 0.20MPa steam heat. Semi-displacement type water heater heater. Water pipe using three polypropylene tube (PP-R) pipes, drainage pipes using PVC pipe (UPVC), fire pipe use steel pipe, hot water pipe use cross-linked polyethylene (PEX). Keywords Water supply fire fighting system drainage sprinkler system |